Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 735
Filtrar
1.
J Urol ; 211(6): 742, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38721936

Assuntos
Humanos , Masculino
2.
Urolithiasis ; 52(1): 66, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630256

RESUMO

The purpose of this study was to measure and compare renal pelvic pressure (RPP) between prone and supine percutaneous nephrolithotomy (PCNL) in a benchtop model. Six identical silicone kidney models were placed into anatomically correct prone or supine torsos constructed from patient CT scans in the corresponding positions. A 30-Fr renal access sheath was placed in either the upper, middle, or lower pole calyx for both prone and supine positions. Two 9-mm BegoStones were placed in the respective calyx and RPPs were measured at baseline, irrigating with a rigid nephroscope, and irrigating with a flexible nephroscope. Five trials were conducted for each access in both prone and supine positions. The average baseline RPP in the prone position was significantly higher than the supine position (9.1 vs 2.7 mmHg; p < 0.001). Similarly, the average RPP in prone was significantly higher than supine when using both the rigid and flexible nephroscopes. When comparing RPPs for upper, middle, and lower pole access sites, there was no significant difference in pressures in either prone or supine positions (p > 0.05 for all). Overall, when combining all pressures at baseline and with irrigation, with all access sites and types of scopes, the mean RPP was significantly higher in the prone position compared to the supine position (14.0 vs 3.2 mmHg; p < 0.001). RPPs were significantly higher in the prone position compared to the supine position in all conditions tested. These differences in RPPs between prone and supine PCNL could in part explain the different clinical outcomes, including postoperative fever and stone-free rates.


Assuntos
Nefrolitotomia Percutânea , Humanos , Nefrolitotomia Percutânea/efeitos adversos , Pelve Renal , Rim/diagnóstico por imagem , Rim/cirurgia , Cálices Renais , Posicionamento do Paciente
3.
Psychiatry Res ; 336: 115897, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38636333

RESUMO

Interoception is defined as the sense of the internal state of the body. Dysfunctions in interoception are found in several mental disorders, including trauma-related conditions. Mindfulness-Based Interventions (MBIs) have been shown to influence interoceptive processes. Randomised controlled trials (RCTs) have investigated whether MBIs impact symptoms and interoception in patients with trauma-related disorders. We undertook a systematic review and meta-analysis to synthesize these data. We included RCTs with an MBI arm which enrolled adult patients with trauma related-disorders or exposure to a traumatic experience, and addressed changes in interoception and trauma-related symptoms. A random-effects multivariate meta-analytic model was performed to quantify group differences in score change from baseline to follow-up. Twelve studies were included in the systematic review, and eleven in the meta-analysis. Overall, MBIs showed small to moderate positive effects on both interoception and symptoms. Despite a high heterogeneity in results, sensitivity analyses confirmed the robustness of the findings. We conclude that the efficacy of MBIs on trauma-related symptoms and interoception is supported by randomised evidence. However, further research is needed to understand whether changes in interoception might underpin the effectiveness of MBIs in trauma-related disorders.


Assuntos
Interocepção , Atenção Plena , Humanos , Atenção Plena/métodos , Interocepção/fisiologia , Transtornos de Estresse Pós-Traumáticos/terapia , Transtornos de Estresse Pós-Traumáticos/fisiopatologia
4.
Urology ; 185: 150-156, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38350550

RESUMO

OBJECTIVE: To compare the radiation dose and image quality between flat panel detector (FPD) and traditional image intensifier (II) C-arms at their lowest radiation settings. METHODS: In a ureteroscopy simulation using a cadaver model, the radiation exposure was compared between FPD and II at 4 pulses-per-second (pps) using both low dose and automatic exposure control (AEC) settings. Additionally, the lowest dose settings for each machine were compared (4 pps with low dose in the FPD and 1 pps with low dose in the II). Five trials of 5 minutes were conducted for each setting. Four new optically stimulated luminescent dosimeters were used in each trial to record radiation exposure. Ten blinded urologists completed a survey rating image quality for each setting. RESULTS: When comparing the FPD and II at their lowest possible settings, the FPD produced significantly more radiation (P <.05). Using both machines at 4 pps in low dose mode resulted in no significant difference between C-arms (P >.05). Conversely, operating the C-arms at 4 pps and AEC resulted in significantly higher radiation exposure from the FPD compared to the II (P <.05). There was no significant difference in image quality at each setting. CONCLUSION: FPDs produce significantly more radiation at the lowest settings compared to IIs. Surgeons should employ IIs when reducing radiation exposure as low as possible is imperative, such as when operating on pediatric and pregnant patients.


Assuntos
Exposição à Radiação , Intensificação de Imagem Radiográfica , Humanos , Criança , Doses de Radiação , Imagens de Fantasmas , Simulação por Computador
5.
J Endourol ; 38(3): 228-233, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38185836

RESUMO

Introduction: Flat-panel detector C-arms (FCs) are reported to reduce radiation exposure and improve image quality compared with conventional image intensifier C-arms (CCs). The purpose of this study was to compare radiation exposure and image quality between three commonly used FCs. Materials and Methods: A cadaver model was placed in the prone position to simulate percutaneous nephrolithotomy. We compared the following three FCs: OEC Elite CFD from GE HealthCare, Zenition 70 from Philips, and Ziehm Vision RFD from Ziehm Imaging. To measure the radiation dose, optically stimulated luminescence dosimeters (OSLDs) were utilized during five 300-second trials, conducted under three settings: automatic exposure control (AEC), AEC with low dose (LD), and LD with the lowest pulse rate (LDLP). Ten blinded urologists evaluated the image quality. Data were statistically analyzed using the analysis of variance (ANOVA) and Tukey's B post hoc tests. Results: In the AEC setting, the Philips C-arm demonstrated lower ventral OSLD exposure (42,446 mrad) compared with both the GE (51,076 mrad) and Ziehm (83,178 mrad; p < 0.001) C-arms. Similarly, in the LD setting, the Philips C-arm resulted in less ventral OSLD exposure (25,926 mrad) than both the Ziehm (30,956 mrad) and GE (38,209 mrad; p < 0.001) C-arms. Meanwhile, in the LDLP setting, the Ziehm C-arm showed less ventral OSLD exposure (4019 mrad) than both the GE (7418 mrad) and Philips (8229 mrad; p < 0.001) C-arms. All three manufacturers received adequate image quality ratings at the AEC and LD settings. However, at LDLP, the Ziehm C-arm received inadequate ratings in 8% of images, whereas both the GE and Philips C-arms received 100% adequate ratings (p = 0.016). Conclusions: Radiation produced by flat-panel C-arms varies dramatically, with the highest exposure (Ziehm) being almost double the lowest (Philips) in AEC. Improved picture quality at the lowest settings may come at the cost of increased radiation dose. Surgeons should carefully select the machine and settings to minimize radiation exposure while still preserving the image quality.


Assuntos
Doses de Radiação , Humanos , Imagens de Fantasmas , Fluoroscopia/métodos
6.
Urolithiasis ; 52(1): 27, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217570

RESUMO

Percutaneous nephrolithotomy confers the highest radiation to the urologist's hands compared to other urologic procedures. This study compares radiation exposure to the surgeon's hand and patient's body when utilizing three different techniques for needle insertion during renal access. Simulated percutaneous renal access was performed using a cadaveric patient and separate cadaveric forearm representing the surgeon's hand. Three different needle-holding techniques were compared: conventional glove (control), a radiation-attenuating glove, and a novel needle holder. Five 300-s fluoroscopy trials were performed per treatment arm. The primary outcome was radiation dose (mSv) to the surgeon's hand. The secondary outcome was radiation dose to the patient. One-way ANOVA and Tukey's B post-hoc tests were performed with p < 0.05 considered significant. Compared to the control (3.92 mSv), both the radiation-attenuating glove (2.48 mSv) and the needle holder (1.37 mSv) reduced hand radiation exposure (p < 0.001). The needle holder reduced hand radiation compared to the radiation-attenuating glove (p < 0.001). The radiation-attenuating glove resulted in greater radiation produced by the C-arm compared to the needle holder (83.49 vs 69.22 mGy; p = 0.019). Patient radiation exposure was significantly higher with the radiation-attenuating glove compared to the needle holder (8.43 vs 7.03 mSv; p = 0.027). Though radiation-attenuating gloves decreased hand radiation dose by 37%, this came at the price of a 3% increase in patient exposure. In contrast, the needle holder reduced exposure to both the surgeon's hand by 65% and the patient by 14%. Thus, a well-designed low-density needle holder could optimize radiation safety for both surgeon and patient.


Assuntos
Nefrolitotomia Percutânea , Exposição Ocupacional , Cirurgiões , Humanos , Nefrolitotomia Percutânea/efeitos adversos , Exposição Ocupacional/análise , Mãos/cirurgia , Fluoroscopia/efeitos adversos , Cadáver , Doses de Radiação
7.
J Endourol ; 38(1): 53-59, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37800857

RESUMO

Introduction: A flexible cystoscope is an indispensable tool for urologists, facilitating a variety of procedures in both the operating room and at bedside. Single-use cystoscopes offer benefits including accessibility and decreased burden for reprocessing. The aims of this study were to compare time efficiency and performance of single-use and reusable cystoscopes. Methods: Ten new Ambu® aScope™ 4 Cysto single-use and two Olympus CYF-5 reusable cystoscopes were compared in simulated bedside cystoscopy and benchtop testing. Ten urologists performed simulated cystoscopy using both cystoscopes in a randomized order. Times for supply-gathering, setup, cystoscopy, cleanup, and cumulative time were recorded, followed by a Likert feedback survey. For benchtop assessment, physical, optical, and functional specifications were assessed and compared between cystoscopes. Results: The single-use cystoscope demonstrated shorter supply-gathering, setup, cleanup, and cumulative times (824 vs 1231 seconds; p < 0.05) but a comparable cystoscopy time to the reusable cystoscope (202 vs 212 seconds; p = 0.32). The single-use cystoscope had a higher image resolution, but a narrower field of view. Upward deflection was greater for the single-use cystoscope (214.50° vs 199.45°; p < 0.01) but required greater force (2.5 × ). The working channel diameter and irrigation rate were greater in the reusable cystoscope. While the single-use cystoscope lacked tumor enhancing optical features, it had higher Likert scale scores for Time Efficiency and Overall Satisfaction. Conclusion: The single-use cystoscope demonstrates comparable benchtop performance and superior time efficiency compared to reusable cystoscopes. However, the reusable cystoscope has superior optical versatility and flow rate. Knowledge of these differences allows for optimal cystoscope selection based on procedure indication.


Assuntos
Cistoscópios , Cistoscopia , Humanos , Desenho de Equipamento , Cistoscopia/métodos , Salas Cirúrgicas , Exame Físico
8.
Can J Urol ; 30(5): 11703-11707, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37838999

RESUMO

INTRODUCTION: Liposomal bupivacaine (LB) is a depot formulation of bupivacaine, which releases the drug over 72 hours to prolong local pain control. This retrospective study compares the effect of using LB versus plain bupivacaine on postoperative pain control, length of hospital stay and cost among patients undergoing vaginal reconstructive surgery. MATERIALS AND METHODS: Patients who underwent vaginal reconstructive surgery with levatorplasty and received an injection of 20 cc of either plain bupivacaine or LB for pudendal nerve block were included. The primary outcomes included postoperative narcotic use and subjective pain score. The secondary outcome was postoperative length of stay. Comparisons between groups were performed using the T test, Mann Whitney U and Chi-square tests with p < 0.05 considered significant. RESULTS: Between June 2016 and December 2021, 25 patients had received LB as a pudendal nerve block and 25 had received plain bupivacaine. Demographics between groups were similar. There was no difference between postoperative morphine equivalent dose (MED) for plain bupivacaine versus LB (25.3 ± 65.8 vs. 24.9 ± 31.7 MED; p = 0.159) or length of hospital stay (15.8 ± 12.0 hours vs. 23.8 ± 20.0; p = 0.094). Furthermore, subjective pain was also similar between groups (0 vs. 1.6 ± 2.6, p = 0.68), (4.6 ± 2.3 vs. 4.9 ± 2.0 average POD 1 pain, p = 0.534) and (4.3 ± 2.1 for vs. 4.9 ± 2.1 average POD 2 pain, p = 0.373). CONCLUSION: LB is not superior to plain bupivacaine for controlling pain following vaginal reconstructive surgery, and justification for the exponentially greater cost of LB is not supported. Prospective investigations with larger sample sizes are needed to determine the optimal pain management for levatorplasty in vaginal reconstructive surgery.


Assuntos
Bupivacaína , Manejo da Dor , Feminino , Humanos , Anestésicos Locais , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos , Estudos Prospectivos , Lipossomos , Analgésicos Opioides
9.
J Endourol ; 37(11): 1221-1227, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37698888

RESUMO

Introduction and Objective: A variety of laser sources are available to treat bladder stones. The aim of this study was to compare time and cost efficiency of the thulium fiber laser (TFL) to four holmium lasers (HLs) with different powers or technologies, including MOSES™ during simulated cystolithotripsy. Materials and Methods: In a benchtop simulation of laser cystolithotripsy, 25 identical 4-cm BegoStones (calcium oxalate monohydrate consistency) were placed on a grid within a 3D-printed bladder model. Lasers were operated at maximal energy, using a 550 µm fiber. Lasers compared were as follows: 60 W TFL, 120 W HL with MOSES, and conventional 120, 100, and 30 W HLs. Five trials were performed for each laser with endpoints of laser time, total time, number of fiber strippings, and total energy. Cost-effectiveness was modeled using laser purchase price, fiber, and operating room (OR) time cost. ANOVA with Tukey's B post hoc was performed to compare outcomes. Spearman's test was used to assess correlation between laser power and procedure time. Results: The laser and total operating times were significantly different between the five systems (p < 0.001). The 120 W HL with MOSES was the fastest with 60.9 minutes of laser and 68.3 minutes of procedure times, while the 30 W HL was the slowest with 281.2 minutes of laser and 297.5 minutes of procedure times. The 60 W TFL was faster than the 30 W HL, but slower than the higher power HLs. Higher laser power was associated with shorter procedure time (Rs = -0.98; p = 0.002). When estimating cost per procedure, the MOSES HL was the cheapest, but had the highest purchase cost. The TFL was not cost-effective for large bladder stones compared with the 100 W HL. Conclusions: When treating large bladder stones, total laser power was highly correlated with laser and procedure times and the TFL was limited by its total power. The most cost-effective laser for use will depend on the case volume.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos da Bexiga Urinária , Humanos , Cálculos da Bexiga Urinária/cirurgia , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Túlio , Oxalato de Cálcio , Hólmio
10.
Int Urol Nephrol ; 55(10): 2439-2445, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37440005

RESUMO

OBJECTIVE: To investigate the impact of renal function on the risk, severity, and management of radiation cystitis in patients who underwent postoperative radiation therapy for prostate cancer. METHODS: Retrospective data was assessed from patients treated with adjuvant/salvage radiation therapy at a single academic institution between 2006 and 2020. The incidence, severity, and management of radiation cystitis were compared between three groups: CKD 0-2, CKD 3-4, and CKD 5. Associations of clinicopathologic factors with radiation cystitis were assessed in univariate and multivariate Cox regression models. RESULTS: A total of 110 patients who underwent radiation therapy following robot-assisted laparoscopic radical prostatectomy were included. The incidence of radiation cystitis following postoperative radiation therapy was 17% with a median presentation time of 34 months (interquartile range 16-65 months). The incidence of radiation cystitis was 100% in CKD 5 patients compared to 15% in CKD 0-2 and 17% in CKD 3-4 patients (p < 0.001). CKD 5 patients required more treatments, emergency department visits, and longer hospitalization times than CKD 0-4 patients (all p < 0.001). Multivariate analyses identified CKD 5 as the only significant factor associated with radiation cystitis (HR = 10.39, p = 0.026). CONCLUSION: End-stage renal failure is associated with the risk and severity of radiation cystitis in patients receiving postoperative radiation therapy. Knowledge of the potential morbidity of this complication in this population could guide physicians and patients as they evaluate risks and benefits prior to selecting adjuvant or salvage radiation therapy.


Assuntos
Cistite , Falência Renal Crônica , Neoplasias da Próstata , Masculino , Humanos , Estudos Retrospectivos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Prostatectomia/efeitos adversos , Falência Renal Crônica/complicações , Cistite/etiologia , Cistite/cirurgia , Terapia de Salvação , Antígeno Prostático Específico
11.
Br Dent J ; 234(9): 634-635, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37173466
12.
Can J Urol ; 29(6): 11371-11377, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36495579

RESUMO

INTRODUCTION: During in situ lower pole laser lithotripsy, the dependent location may result in increased challenge fragmenting stones and a risk for stone regrowth if residual fragments remain. The purpose of this study was to compare the thulium fiber laser (TFL) with the holmium laser (HL) for in situ lower pole lithotripsy. MATERIALS AND METHODS: In a 3D printed kidney benchtop model, sixty 1 cm BegoStones were placed in the lower pole and fragmented in situ until fragments passed through a 2 x 2 mm mesh. Laser lithotripsy was performed using twelve energy, frequency and fiber size combinations and residual fragments were compared. In addition, laser fiber diameters and subsequent ureteroscope deflections and flow rates were compared between fibers. RESULTS: The TFL resulted in decreased residual fragments compared to the HL (11% vs. 17%, p < 0.001) and the three settings with least residual fragments were all TFL. Compared to the 150 µm TFL (265° deflection), there was a loss of 9° and 34° in the 200 µm TFL and 272 µm HL fibers, respectively. The measured fiber sizes were greater than manufacturer specified fiber size in every instance. Irrigation rates inversely correlated with fiber size. CONCLUSION: The TFL resulted in 35% less residual stone fragments, up to 34° additional deflection, and an increased irrigation rate when compared to the HL. Optimal fragmentation settings are identified to further improve lower pole lithotripsy. The combination of reduced residual fragments, improved deflection, and better flow rates make the TFL advantageous for in situ lower pole lithotripsy.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Litotripsia a Laser/métodos , Túlio , Hólmio , Lasers de Estado Sólido/uso terapêutico , Ureteroscópios
13.
Environ Sci Technol Lett ; 9(9): 733-738, 2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36118959

RESUMO

We compared the sensitivity of closely related Pacific salmon and steelhead (Oncorhynchus spp.) to untreated urban stormwater runoff across three storm events. Juvenile coho, sockeye, steelhead, and Chinook were exposed for 24 h to untreated urban runoff and then transferred to clean water for 48 h. As anticipated from previous studies, coho were highly susceptible to runoff toxicity, with cumulative mortality rates ranging from 92%-100% across the three storms. By contrast, juvenile sockeye were unaffected (100% survival), and cumulative mortality rates were intermediate for steelhead (4%-42%) and Chinook (0%-13%). Furthermore, coho died rapidly following the onset of stormwater exposure (generally <4 h), whereas mortality in Chinook and steelhead was delayed by 1-2 days. Similar to previous findings for coho, steelhead and Chinook did not recover when transferred to clean water. Lastly, significant mortality occurred in coho even when roadway runoff was diluted by 95% in clean water. Our findings extend the urban runoff mortality syndrome in salmonids and point to a near-term need for sublethal studies in steelhead and Chinook to more precisely understand stormwater risks to threatened species recovery efforts in the western United States.

14.
J Endourol ; 36(9): 1249-1254, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35302382

RESUMO

Introduction and Objective: The novel thulium fiber laser (TFL) has been shown to break stones more rapidly than the holmium:YAG laser (HL). However, some evidence suggests that the TFL generates more heat. The purpose of this study is to compare ureteral temperatures generated by these lasers during ureteroscopic laser lithotripsy in a benchtop model. Methods: A 1-cm BegoStone was manually impacted in the proximal ureter of a three-dimensional printed kidney-ureter model and submerged in 35.5°C saline. Lithotripsy was performed using a 7.6F flexible ureteroscope and a 200 µm laser fiber without a ureteral access sheath. The Dornier 30 W HL, Olympus 100 W HL, and Olympus 60 W TFL were compared. A needle thermocouple to measure temperature was inserted 2 mm from the laser tip. Irrigation was maintained at 35 cc/minute at room temperature using the Thermedx FluidSmart System. Intraluminal temperature was continuously recorded for 60 seconds of laser activation. Five trials were performed for each of four different power settings: 3.6, 10, 20, and 30 W. Analysis of variance and Mann-Whitney U tests were performed with p < 0.05 considered significant. Results: Intraureteral fluid temperature increased as laser power settings increased for all lasers (p < 0.05). The TFL generated higher average ureteral fluid temperatures than the Dornier and Empower HL at all power settings tested (p < 0.001). The maximum temperature for the TFL was higher than the Dornier and Empower HL at all power settings tested (p < 0.001), except at 20 W with the Empower HL. At 30 W, the TFL exceeded 43°C, the threshold for tissue damage. Conclusions: The TFL generated more heat at all settings tested. Supraphysiologic ureteral temperatures may be generated with extended use at high energy settings and low irrigation rates. Understanding the heat generation properties of both lasers could help improve the safety of ureteroscopic laser lithotripsy.


Assuntos
Queimaduras , Lasers de Estado Sólido , Litotripsia a Laser , Ureter , Hólmio , Humanos , Lasers de Estado Sólido/efeitos adversos , Litotripsia a Laser/métodos , Túlio , Ureter/cirurgia , Ureteroscópios
15.
Can J Urol ; 28(5): 10841-10847, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34657657

RESUMO

INTRODUCTION: Obstructing stones with infection represent a true urologic emergency requiring prompt decompression. Historically the systemic inflammatory response syndrome (SIRS) criteria has been used to predict outcomes in patients with sepsis. The quick Sequential Organ Failure Assessment (qSOFA) score has been proposed as a prognostic factor in patients with acute pyelononephritis associated with nephrolithiasis. However there has been limited application of qSOFA to patients undergoing ureteral stenting with obstructive pyelonephritis. The purpose of this study was to evaluate the predictive value of the qSOFA score for postoperative outcomes following renal decompression in this patient population. MATERIALS AND METHODS: A retrospective review was conducted at three medical centers within one academic institution to identify patients with obstructive pyelonephritis secondary to ureteral stones. All patients underwent emergent ureteral stent placement for decompression. The primary outcome was the predictive value of preoperative qSOFA score ≥ 2 for intensive care unit (ICU) admission postoperatively. Univariate analysis and multivariate regression analysis were performed to identify factors associated with postoperative outcomes, with p < 0.05 considered significant. RESULTS: Of the 289 patients who had ureteral stents placed, 147 patients met inclusion criteria. Twenty-four (16.3%) patients required ICU admission and there were 3 (2%) mortalities, all of these within the ICU admission group. The sensitivity and specificity of the qSOFA score ≥ 2 for ICU admission was 70.8% and 79.5% respectively which outperformed SIRS criteria, which had a sensitivity and specificity of 100% and 33.6% respectively. CONCLUSION: A preoperative qSOFA score ≥ 2 was a significant predictor for postoperative ICU admission in patients undergoing ureteral stent placement for obstructive pyelonephritis. The qSOFA score can be used to determine which patients will require ICU admission.


Assuntos
Pielonefrite , Cálculos Ureterais , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Escores de Disfunção Orgânica , Prognóstico , Pielonefrite/complicações , Curva ROC , Estudos Retrospectivos , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Cálculos Ureterais/complicações , Cálculos Ureterais/cirurgia
16.
Compr Psychiatry ; 104: 152212, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33160123

RESUMO

BACKGROUND: Clinical audit is a sustained cyclical quality improvement process seeking to improve patient care and outcomes by evaluating services against explicit standards and implementing necessary changes. National audits aim to improve population-level clinical care by identifying unwarranted variations and making recommendations for clinicians, managers and service commissioners. The National Clinical Audit of Anxiety and Depression aimed to improve clinical care for people admitted to English hospitals for treatment of anxiety and depression, to provide comparative data on quality of care, and to support local quality improvement initiatives by identifying and sharing examples of best practice. PROCEDURES: Thirteen standards were developed based on NICE guidelines, literature review and feedback from a steering committee and reference group of service users and carers. All providers of NHS inpatient mental health services in England were asked to submit details of between 20 and 100 eligible service users/patients admitted between April 2017 and September 2018. To ascertain data reliability, participating services re-audited 5 sets of case-notes with a second auditor, and the coordinating team checked 10 randomly-selected sets of case-notes from 3 services, also selected at random. The reference group and steering committee identified key findings and developed a series of recommendations, which were discussed in regional quality improvement workshops and on-line webinars. FINDINGS: Data from 3795 case notes were analysed. A sizeable proportion of records indicated that at least one important aspect of initial assessment was not documented. Many service users/patients who could have benefited from an intervention targeted at optimising physical health did not receive it. Only a minority (39%) were referred for psychological therapy. Use of outcome measures varied considerably but no single outcome measure was being used routinely. Most individuals had a care plan recorded in the notes, but a review date was documented in only two-thirds, and almost half of individuals had not received a copy. CONCLUSIONS: There was considerable variation between English mental health services across many variables, and much scope for improvement. Clinicians should ensure that care plans are developed collaboratively with service users/patients and identified carers should be provided with information about support services. Health services should investigate the reasons for low referral rates for psychological therapies. Clinicians should ensure all service users have jointly developed crisis plans in place at discharge. Service managers should agree outcome measures to evaluate the treatment provided and clinicians should use these measures at initial assessment and review appointments. The implementation of such changes provides an opportunity for collaborative research into mental health service delivery and quality.


Assuntos
Transtorno Depressivo , Serviços de Saúde Mental , Ansiedade , Auditoria Clínica , Depressão/diagnóstico , Depressão/terapia , Transtorno Depressivo/diagnóstico , Transtorno Depressivo/terapia , Humanos , Pacientes Internados , Reprodutibilidade dos Testes
19.
Urology ; 145: 299-300, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32717249

RESUMO

INTRODUCTION: Calculi encountered in the lower urinary tract typically reside within the bladder, less often in the urethra. In this video, we present a minimally invasive endoscopic approach for removal of the largest total stone volume in the lower urinary tract reported in the literature to date. METHODS: A 25-year-old male (body mass index 61 kg/m2) with neurogenic bladder presented with urosepsis and acute kidney injury secondary to obstructive uropathy. Computerized tomography (CT) of the abdomen and pelvis demonstrated bilateral severe hydroureteronephrosis, a 4.2-cm bladder stone, and 3 urethral stones, including a 7.7-cm prostatic urethral stone and 2 membranous urethral stones (Fig. 1). Urgent bilateral percutaneous nephrostomy tubes were placed. The patient elected for endoscopic management. RESULTS: The patient was placed in the supine lithotomy position. His buried penis and narrow urethra only accommodated a 16-French flexible cystoscope. Multiple stones were encountered in the membranous urethra. A 60-W SuperPulse Thulium Fiber laser at 2 J and 30 Hz was utilized to dust the urethral stones efficiently. Simultaneous ultrasound-guided percutaneous access into the bladder was obtained and ultrasonic lithotripsy via shockpulse was used to clear the bladder stone and prostatic stone from above. Total stone treatment time was 240 minutes. Suprapubic and urethral catheters were placed at the conclusion. Postoperative day 1 CT scan confirmed stone-free status and he was discharged postoperative day 2. Outpatient nephrostogram demonstrated patency of bilateral ureters and nephrostomy tubes were removed. CONCLUSION: Higher morbidity procedures including open or laparoscopic approaches have been described for management of large lower urinary tract stones. In this video, we demonstrate a minimally invasive approach of combined simultaneous antegrade and retrograde lithotripsy to achieve a stone-free status in this morbidly obese and complicated patient.


Assuntos
Cálculos/cirurgia , Cistoscopia/métodos , Doenças Prostáticas/cirurgia , Doenças Uretrais/cirurgia , Cálculos da Bexiga Urinária/cirurgia , Cálculos Urinários/cirurgia , Adulto , Cálculos/patologia , Humanos , Masculino , Doenças Prostáticas/patologia , Doenças Uretrais/patologia , Cálculos da Bexiga Urinária/patologia , Cálculos Urinários/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...